Monarch SLS-115/230 User Manual

Browse online or download User Manual for Laser levels Monarch SLS-115/230. Monarch SLS-115/230 User's Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 8
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
SLS-115/230
Smart Laser Sensor
MONARCH INSTRUMENT
Instruction Manual
15 Columbia Drive
Amherst, NH 03031-2334 USA
Phone: (603) 883-3390
Fax: (603) 886-3300
Website: www.monarchinstrument.com
Printed in the U.S.A.
Copyrighted by Monarch Instrument 2004, all rights reserved
1071-4859-111
CE DECLARATION OF CONFORMITY
As Manufacturer:
Monarch Instrument
Division of Monarch International Inc.
15 Columbia Drive, Amherst NH 03031 USA
declares under Monarch’s sole responsibility that the product:
to which this declaration relates is in conformity with the following directives and
standards when installed and operated in accordance with the user manual:
References: Retlif Testing Laboratories, (Report No. R-4283)
Technical Construction File SLS-0604 of June 2004
SLS - Smart Laser Sensor
15
th
June 2004
Manufacturer (Amherst,NH) Alan Woolfson, VP Engineering (Authorized Signature)
Directives: EMC 89/336/EEC
Low Voltage 73/23/EEC
Standards: EMC: EN61326:1997
Electrical Safety: IEC61010-1:2001
Laser Safety: IEC60825-1:2001
Page view 0
1 2 3 4 5 6 7 8

Summary of Contents

Page 1 - Smart Laser Sensor

SLS-115/230Smart Laser SensorMONARCH INSTRUMENT Instruction Manual15 Columbia DriveAmherst, NH 03031-2334 USAPhone: (603) 883-3390Fax: (603) 886

Page 2 - 11.0 ACCESSORIES

SAFEGUARDS AND PRECAUTIONSWARNING - This product emits a visible beam of laserlight. Avoid exposure to the laser radiation. The use ofoptical viewin

Page 3 - 9.0 RS232

TABLE OF CONTENTSTABLE OF CONTENTSSymbols on the unit and in this manual:Warning Direct currentLaser BeamCaution Alternating currentRead Manual1.0 SMA

Page 4

11.0 SMART LASER SENSOR SPECIFICATIONSLaser Specifications:Classification: Class 3R (per IEC 60825-1 Ed 1.2 2001-8)Complies with FDA performance stand

Page 5 - 6.0 OPERATION

2Max RPM: 500,000 RPMMin. Trigger Duration: 10 µsecIndicators: LEDs for On Target, Laser On, Auto/Gain, Power/ChargeModes: Normal (manual) or Auto, an

Page 6

3Pulse Output (continued):Polarity: Positive or Negative pulse (switch selectable)RS232: Transmit Out – ASCII value of RPM (Accuracy ±0.002% of readi

Page 7 - 2.0 OVERVIEW

4Weight: 10.6 oz (300.5 grams) excluding cable and chargerCompliance: CE 93/68/EEC EMC directive (EN 61326:2001)IEC 61010-1 2001, IEC 60825-1 2001, C

Page 8 - 4.0 QUICK START GUIDE

53.0 INDICATORS AND SWITCHES1. On Target LED Lit whenever the sensor is receiving areflected signal back from the target. As thefrequency increases,

Comments to this Manuals

No comments